CapitalBio SmartArrayer 136 is designed for large-scale microarray printing of up to 136 slides or up to 17 96-well plates. The SmartArrayer 136 is equipped with dual systems of contact printing and non-contact dispensing. The multi-purpose microarray spotter prints liquid samples on various substrates, such as glass, silicon, microplates or membranes, with high precision, maximum flexibility.
◆ Dual printing: Exchangeable contact spotting module and non-contact Microdispense™ module.
◆ Substrate versatility: Standard decks applicable to glass slides, silicon substrates and microplates
◆ Higher capacity for slide loading (up to 136) or plate loading (up to 17) in a single round to meet the needs of large-scale microarray production.
◆ High speed: Precise X, Y spotting motion up to 300 mm/sec velocity and 3,000 mm/sec² acceleration when 32 pins are fitted.
◆ Highly efficient cleaning: Selectable combinations of sonication, active washing and vacuum drying.
◆ Pneumatic Non-contact Microdispense™ technology: Ensures no direct contact with slide substrates for less contamination and higher sample utilization rates.
◆ Application flexibility: Microdispense™ volumes adjustable from 10nl to 50µl.
◆ User-friendly software: Flexible array design tools and representative graphical previews of slides/plates/arrays/samples.
◆ Controlled printing environment: HEPA filter, humidity control.
| Up to 136 slides spotting | Up to 17 plates spotting |
CapitalBio SmartArrayer 136 spotters can print up to 200 high content microarray slides with 30,000 + spots per week, or up to 200 diagnostic microarray slides with 300 assays in a day.
![]() |
Create, save and load your own combinations of cleaning steps and choose the number of repeated cleaning cycles.
For spotting: |
For dispensing: |
Contact spotting | Non-contact dispensing | |
Capacity | 136 slides /16 96-well plates | 136 slides /17 96-well plates |
Positioning Repeatability | ±3 μm | |
Positioning resolution | 1.2 μm (X and Y axis); 0.6 μm (Z axis) | |
No. of pins | 4 (8, 16, 32,48 optional) | 1 (2, 4 optional) |
Single round completion time(including pinhead wash) | <140 s | <160 s |
Minimum sample delivery volume* | 0.5 nl | 10 nl |
Minimum sample loading volume* | 0.25 μl | 3 μl |
Spot diameter | ≥62.5 μm | ~400 μm |
Voltage | AC 110 V/AC 220 V | AC 110 V/AC 220 V |
Power | 1,500 Watts | 1,500+400 Watts |
*Subject to the type of contact pin or non-contact dispenser used
Cat. No. | Product Name | Product Description |
100040 | CapitalBio SmartArrayer 136 Microarray Dual Spotter | Dual systems of contact spotting and non-contact dispensing on slides |
100050 | CapitalBio SmartArrayer 136 Microarray Contact Spotter | Contact spotting on slides |
100060 | CapitalBio SmartArrayer 136 Microarray Dispense Spotter | Non-contact dispensing on slides |
440010 | CapitalBio DNA Spotting Buffer | 5 ml, 25 ml/package |
440015 | CapitalBio Protein Spotting Buffer A | 5 ml/package |
440016 | CapitalBio Protein Spotting Buffer B | 5 ml/package |